Configuration – Parker Products COMPAX-M /-S (L) User Manual

Page 85

Advertising
background image

Configuration

Machine zero mode

85

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

P212="4" (only permitted for COMPAX XX00 and COMPAX XX30!)

Find machine zero.

Application

P213="0"

clockwising rotating motor

encoder zero pulse

MN-Ini

P29 = 0°- 360°

position of the actual MZ

signal MZ-ini.

0° 360°

Linear and rotatory
movements.
If you have an encoder
on the load, with this
setting you obtain a
reproducible machine
zero response to any
transmission factor
which does not round
to whole digits (i.e. not
precisely displayable).

P213="1"

clockwise rotating motor

encoder zero pulse

MN-Ini

position of the actual MZ

P29 = 0°-360°

signal MZ-ini.

0° 360°

Example of an
transmission factor
that cannot be
displayed exactly:

teeth

11

teeth

17

Note!
If P75

0 for this setting, external position localization is switched on.

External encoder; read via an encoder input module (E2, E4)

Encoder input parametrized by: P144="6"
Specify P98 (travel per encoder revolution), P214 (encoder direction) and P143
(encoder pulse number).

Machine zero
equals external
initiator &
external zero
pulse

Conditions for
this operating
mode:

Advertising