Equipment replacement, Switch-on status, 3 equipment replacement – Parker Products COMPAX-M /-S (L) User Manual

Page 12: Compax-m / -s, Previous software ≥≥≥≥ v2.0, Transferring system parameters, Previous software ≤≤≤≤ v2.0

Advertising
background image

Switch-on status

COMPAX-M / -S

12

5.3 Equipment

replacement

Previous software

≥≥≥≥

V2.0

!

Procedure for copying the complete COMPAX setting onto a new unit

!

Start ServoManager.

!

Connect old COMPAX via RS232.

!

Use menu "Insert: Axis: From controller" to set up an axis which contains all
COMPAX settings (all parameters: including system parameters, data records
and (with COMPAX XX70) existing curves).

!

Connect new COMPAX.

!

Use menu "Online: Download" to transfer data (without system parameters

1

) into

the new COMPAX.

Transferring system parameters

!

Call up ParameterEditor (Menu: PC Tools: ParameterEditor)

!

Use menu "Online: Copy" menu to transfer all parameters (including system
parameters) to COMPAX.

Previous software

≤≤≤≤

V2.0

Procedure for copying the complete COMPAX setting onto a new unit

!

Start ServoManager.

!

Connect old COMPAX via RS232.

!

Use menu "Insert: Axis: New" to set up a new axis.

!

Use menu "Online: Upload" to load all COMPAX settings (all parameters:
including system parameters, data records, and (in COMPAX XX70) existing
curves) into the new axis.

!

Connect new COMPAX.

!

Use menu "Online: Download" to transfer data (without system parameters) into
the new COMPAX.

Transferring system parameters

!

Call up ParameterEditor (Menu: PC Tools: ParameterEditor)

!

Use menu "Online: Copy" menu to transfer all parameters (including system
parameters) to COMPAX.

1

System parameters are internal parameters; you will only obtain an identical

COMPAX – setting if these are also transferred.

Advertising