Read and write program sets and parameters, Interfaces, 3 read and write program sets and parameters – Parker Products COMPAX-M /-S (L) User Manual

Page 163: Read the status values

Advertising
background image

Interfaces

RS232 interface

163

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

Direct modification of velocity of an active positioning process.

The type of speed transfer and the ensuing braking ramp can be influenced by

previously modified acceleration times (ACCEL, ACCEL-).

Instruction

Abbreviated
form

Meaning

POSR 0 SPEED
value

PR 0 SD

Direct speed modification.

These commands are processed regardless of a positioning process specified by

the interface (not during an internal data record procedure).

Instruction

Abbreviated
form

Meaning

OUTPUT

OT

Set output

GOTO

GO

Adjusts data record indicator
and enables / blocks password.

The axis must be at a standstill if modified VP parameters are to be transferred.

The axis must be switched off if modified VC parameters are to be transferred

(e.g. via OUTPUT O0=1).

Instruction

Abbreviated
form

Meaning

VALID
PARAMETER

VP

Modified parameter accepted (not
configuration parameters).

VALID
CONFIGURATION

VC

All parameters are accepted with VC.

Use the serial interface to query all status values, even during a positioning
process.

Sxx

transmitted, xx = number of the status value.

COMPAX returns the current value.

Example: S1

C

R

L

F

Response: S001:xxxxxxxx,xxxmm C

R

L

F

>

The decimal point for S1 - S12 is always the ninth digit after the ":".

8.6.3.3 Read and write program sets and parameters

Also possible during a positioning process.

Instruction

Meaning

Nxxx: Instruction

Write set xxx with instruction.

Pxxx=value

Write parameter xxx with value.

Pxxx="name"

(Only for P40-P49)

Assigns parameter xxx with name.

Example:

N005: POSA 100 C

R

L

F

or N005: PA 100 C

R

L

F

The POSA 100 instruction is written in data record 5.

Instruction

Meaning

Nxxx

Read data record xxx.

Pxxx

Read parameter xxx.

Commands which
are not position-
dependent

Commands which
are only permitted
when drive is idle

Read the status
values

Download: writing
the sets and
parameters

Upload: read the
sets and
parameter