126

Optimization
process:

Note

The arrows behind the parameters show the preferred

direction for the parameter optimization.

Reduce parameter

Increase parameter

↓↑

Both directions could lead to a better setting.

The optmizing direction shown usually leads
to a good control result in our experience:
however, this cannot apply to every
application case!

Sensor

?

Select structure/parameter
variant 1
P59=4

(Optimise P24 if necessary)

Select structure/parameter
variant 2
P59=3

(Optimise P24 if necessary)

Set motor
Configure drive type:
Parameters P81 ... P92

Motor with

resolver

Motor with

SinCos

Increase control dynamic

Increase P23

Travel slowly over the positioning range

stable, quiet travelling

unstable, unquiet travelling

(no longer corresponds to to the requirements)

Reset P23 to the last setting

User-defined settings

Modify P56

↓↑

(D section rpm controller)

Increase P23

Travel slowly over the positioning range

stable, quiet travelling

unstable, unquiet travelling

(no longer corresponds to to the requirements)

Reset P23 & P56 to the last setting

Implement the same process for P57

(lag D

sectionl), P58

(lag rpm filter) and P151

↓↑

(monitor speed)!

Optimizing the movement cycle

Optimise pre-control parameters P25

↓↑

(rpm

pre-control), P26

(acceleration pre-control), P69

(current pre-control) and P70

(return pre-

control).

Check current restriction:

During acceleration/braking, the current limit
should not be reached or only briefly.
The optimizing display (P233/234=13 and 14)
shows the time in which the controller is operating
at the current limit.
Use the pre-control parameters or increase
ACCEL to reduce the "time at current limit".

Further

optimization?

Further

optimization?

User-defined settings with variant 3

(P59= 8)

Modify P56

↓↑

(D section rpm controller)

Increase P23

Travel slowly over the positioning range

stable, quiet travelling

unstable, unquiet travelling

(no longer corresponds to to the requirements)

Reset P23 & P56 to the last setting

Implement the same process for P57

(lag D

section), P58

and (lag rpm filter)!

yes

yes

no

no

Evaluate results.

Set best result.