Connections to the motor, Packaging, Packaging of device – Parker Products COMPAX-M /-S (L) User Manual

Page 49

Advertising
background image

Connections to the motor

49

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

MOK21 (max. 18,9A)

CY-JZ 7x2,5
No. 102-508902

PE

Br. -24V

Br. +24V

W

V

U

PE

Br-

Br+

W

V

U

MOK21

30 mm

30 mm

30 mm

110 mm

75 mm

110 mm

75 mm

35 mm

15 mm

10 mm

190 mm

20 mm

170 mm

15 mm

10 mm

sw1/sw

sw2/br

sw3/bl

sw4/rt

sw5/gr

sw6

gn/ge

standard/hochflex

black1/black

black2/
brown

black3/blue

black4/red

black5/
green

black6

green-yellow

standard/highflex

Version in high-flex: MOK14 (same layout)

MOK11 (max. 32.3A) in high-flex (same layout to MOK21, however in 6 mm

2

)

MOK46 (max. 47.3A) in high-flex (same layout to MOK21, however in 10mm

2

)

Packaging

Packaging of device

Material:
6 x crimping sleeves.
6 cm shrink-fit hose.

Procedure:

Strip 110 mm sheathing off cable.

Cut sheath down to approx. 35 mm, loosen,

fold back over outer cover (approx. 75 mm) and stick with insulating tape.

Shorten sw1,sw2,sw3,sw4,sw5 ca. 15 mm (gn/ge approx. 15 mm longer) cut down sw6.

Attach 2 x approx. 30 mm shrink-fit hose (sticky).

Strip 10 mm of insulation off ends of wires and secure with crimping sleeves 2.5.

Packaging of motor in accordance with manufacturer's specification

Strip 190 mm sheathing of cable.

Cut sheath down to approx. 170 mm, stick remaining 20 mm with insulating tape.

Shorten sw1,sw2,sw3,sw4,sw5 by approx. 15 mm (gn/ge approx. 15 mm longer) cut down sw6.

Strip 10 mm of insulation of ends of wires and secure with crimping sleeves 2.5.

Shrink-fit hose

Advertising