Absolute positioning [posa, Relative positioning [posr, Operating instructions – Parker Products COMPAX-M /-S (L) User Manual

Page 96: Compax-m / -s, 1 absolute positioning [posa, 2 relative positioning [posr, Posa, Posr

Advertising
background image

Operating Instructions

COMPAX-M / -S

Absolute positioning [POSA]

96

8.4.1 Absolute positioning [POSA]

Reference point is real zero (RZ).
Positioning is executed with the acceleration speed set using ACCEL and the
velocity set using SPEED. If these values have not previously been set, substitute
values will apply:
SPEED: parameter P2;

ACCEL: parameter P6

(see Page 212)

POSA value

Value:

figure with two digits after the decimal point (three for inches) in the unit
defined in P90; a control parameter (P40..P49) or a variable (V1..V39)
e.g. POSA .P40
The range is defined by the software end limits P11 and P12.

N005: POSA 150.50

Absolute positioning to +150.5 units

N006: POSA -500

Absolute positioning to -500 units

A position approached manually can be transferred as a POSA command into a

previously selected data record using "TEACH data record" (via an interface).

POSA HOME command via interface triggers "find machine zero".

POSA HOME is not permitted in the COMPAX – program.

When in continuous mode, relative positioning is also adopted with POSA.

8.4.2 Relative positioning [POSR]

The reference point is the current position.

POSR value

Value:

two digits after the decimal point (three for inches) in the unit defined in
P90; a control parameter (P40..P49) or a variable (V1..V39)
e.g. POSR .P40

The range is defined by the software end limits P11 and P12.

N005: POSR 2000
N006: POSR-100.25

Relative positioning by +2000
Relative positioning by -100.25

The positioning commands POSR and POSA can be controlled using binary input I15 "Fast start". This
function is switched on using P18. COMPAX then waits until I15="1" before it executes POSR or
POSA (see Page 151).

POSA

Syntax:

Example:

Additional function:

POSR

Syntax:

Example:

POSA

POSR

SPEED

ACCEL

OUTPUT

Password

SPEED

SYNC

Mark

reference

POSR

SPEED

POSR

OUTPUT

Cam

controller

WAIT

GOTO

GOSUB

RETURN

END

REPEAT

IF I..

Comparison

WAIT Start

GOTO /

GOSUB EXT

IF Error/ Stop

Arithmetic

Position

monitoring

Idle display

Speed

monitoring

Engage /

disengage

brake / final

stage

Variable

voltage