8.5.3 Optimization

display

The optimization display (status S13 and S14) is an aid for optimizing COMPAX
without the need for an additional visual aid. It provides access to the characteristic
parameters of the positioning process (optimization parameters).
From a selection of 14 different parameters for the positioning process, you can
assign 2 parameters to the status values S13 and S14 by using the parameters
P233 (S13) and P234 (S14).
The optimization parameters are reset before each new positioning process and
they are continually updated during the positioning process.

P233/P234

30

Meaning

1

Positioning time (from start of positioning to "Position reached")

2

max. intermediate circuit voltage in [V]

3

reserved

4

max. undershoot referenced to max. position (amount) (only for
highly shifted loops)

5

max. position overshoot [units corresp. P90] (amount)

6

max. position undershoot [units corresp. P90] (amount)

7

max. acceleration lag error [units corresp. P90]

8

max. braking lag error [units corresp. P90]

9

max. acceleration speed in [%] of motor nominal speed

10

max. braking speed in [%] of motor nominal speed

11

max. acceleration current in [%] of motor nominal current

12

max. braking current in [%] of motor nominal current

13

max. time in current limit for acceleration, in [ms]

14

max. time in current limit for braking, in [ms]

56

square of peak motor current (reference value: 80 000A

2

)

Enter the corresponding number in the first column in the parameter. This means

P233 determines status S13

!

P234 determines status S14

positive sense

of rotation

negative sense

of rotation

negative sense

of rotation

max.

position overshoot

max.

position undershoot

max position overshoot

max.

position undershoot

positive sense

of rotation

50

25

0

-25

position

time

5

5

6

6

30

P233/P234 are set as valid with VP

Optimization
parameters:

Description of
optimization
parameters