Optimization functions

Optimization parameters

131

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

Control processes for optimization

Targets / problems

Stiff-
ness

(P23)

Damp-

ing (P24)

Advance contr.

factors (P25,

P26, P70)

Acceleration

time

(ACCEL)

Ramp

shape

(P94)

Other

measures

Minimizing lag error

increase

-

=100%

optimize if

necessary

increase

-

-

No harmonies

-

increase

decrease

increase

quadratic

(P94="3")

increase max.

torque (P16)

Unusually high
harmonies caused
by power limitation

decrease

decrease

decrease

increase

linear

(P94="1")

increase max.

torque (P16)

Vibrating at higher
frequencies
(perceptible as noise)

decrease

decrease

-

-

-

check min. mass

(P92) and min.

moment of inertia

(P81).

Vibrating at lower
frequencies
(perceptible as
motion)

-

increase

-

-

-

check max. mass

(P88) and max.

moment of inertia

(P82).

High motor or final
stage temperatures

decrease

-

-

increase

linear

(P94="1")

decrease max.

torque (P16)