Technical data / connections of inputs and outputs, Start-up manual, Compax-m / -s – Parker Products COMPAX-M /-S (L) User Manual

Page 54

Advertising
background image

Start-up manual

COMPAX-M / -S

Technical data / Connections of inputs and outputs

54

7.9.3 Technical data / Connections of inputs and outputs

0

1 over 9.15V means that "1" is recognised

1

0 over 8.05V means that "0" is recognised

1. O1...O16

Total of max. 1.6A

2. O1...O4, O5...O8,

O9...O12, O13...O16

Per group of 4, max. 0.8A; taking due account of 1.

3. O

per output, max. 0.3A and 40nF capacitive

4

; taking

into account 1. and 2.

Per output, max. 0.3A

In total a sum load for all 8 outputs of max. 0.48A and

40nF capacitive

5

;

If overload occurs, an error message appears (E43: can be acknowledged with
Power off/on); the corresponding group of four is switched off.

10nF

22K

12K

F23

22K

X8/7

PLC

24V

0V

X11/1

X11/2

22K

X11/7

100K

X19/23

X19/14

X19/.

(X19 applies for COMPAX 1000SL)

F23

PLC

24V

0V

X8/15

4.7K

X19/14

X11/1

X11/2

X11/7

X19/23

X19/.

(X19 applies for COMPAX 1000SL)

For reasons of interference protection, we would recommend that you use a
screened cable for the digital inputs and outputs.
With COMPAX 1000SL, the screen is connected with the Sub-D housing.
A protective connection is required when there is inductive load present.

F23

24V

0V

X8/15

4.7K

X19/23

X19/14

X11/1

X11/2

10nF

22K

12K

22K

X8/7

24V

0V

X11/2

22K

F23

100K

X19/.

X19/14

X19/.

X19/23
X11/1

(X19 applies for COMPAX 1000SL)

4

A maximum of 4 COMPAX – inputs can be connected to one output.

5

A maximum of 4 COMPAX – inputs can be connected to one output.

Detection of input

signals:

Load on outputs

(not applicable for

COMPAX 1000SL):

Load on outputs for

COMPAX 1000SL:

Input connection

using I7 as an

example

Output connection

using O7 as an

example

Input/output

connection for

2 COMPAXs

1st COMPAX

2nd COMPAX

COMPAX

COMPAX

Advertising