Configuration, Machine zero equals a limit switch, Teach machine zero – Parker Products COMPAX-M /-S (L) User Manual

Page 87

Advertising
background image

Configuration

Machine zero mode

87

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

P212 ="8"

Find machine zero

Application

P213="0"

clockwise rotating motor

E2

P29 = 0°- 360°

position of actual MZ

signal MZ-ini.

E1

360°

...

resolver zero
pulse

Linear movements.
No need for a machine
zero initiator.

Function

Travels during "Find
machine zero":

to the relevant limit

switch.

back to the 3rd

resolver zero pulse.

The 3rd resolver zero
pulse is evaluated as
machine zero.

P213="1"

clockwise rotating motor

E2

P29 = 0°- 360°

position of actual MZ

signal MZ-ini.

E1

360°

...

resolver zero
pulse

Supplement
With P202, the distance
between initiator and
machine zero can be
increased (e. g. for large
gear ratios). Meaning:
P202=0 or 3; function as
described.
With P202>3, the
distance of the machine
zero can be moved by
further resolver zero
pulses.
P202 unit:
Resolver zero pulses =
motor revolutions

P217 ="1"
P216 = set correctly.
In the above diagram: P216="1": (limit switch E1 is approached with anti-clockwise
rotating motor)

The input of the machine zero initiator (X17/7) must be wired up with the relevant
limit switch:
P213="0": X17/8 must be connected to X17/7.
P213="1": X17/9 must be connected to X17/7.

P212="10": Teach machine zero

When activated via the command "Find machine zero" (Input I1&I2 or
command "POSA Home"), the current position of the motor is defined
as the machine zero.

A machine zero initiator is not required with this method.

Via parameter P29, machine zero can be moved from the teached point by up to
one motor revolution. The drive then executes machine zero travel from the current
position by the angle P29 in a clockwise direction.
Range of values for P29: 0...360 degrees (other values are considered as 0).

If P29=0, machine zero travel is not implemented.

Machine zero
equals a limit
switch

Condition:

Wiring up:

Teach machine
zero