Installation and dimensions of compax 35xxm, Compax 35xxs unit features, 2 installation and dimensions of compax 35xxm – Parker Products COMPAX-M /-S (L) User Manual

Page 27: Mains supply fuse protection, Regeneration mode, Specific technical data, Installation and dimensions of compax 35xxm 27, Fuse protection: max. 16a

Advertising
background image

COMPAX 35XXS unit features

Installation and dimensions of COMPAX 35XXM

27

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

L1

L2

L3

PE

PE

PE

+

-

U

V

W

PE

+

-

F1

Mains Input

DC - In

Braking

Motor

Motor

X 20

24 V

X 21

Resistance

X 22

X 1

Brake

X 23

motor

AC - voltage

up to 500V AC

24V control

voltage

external

ballast

resistor

motor

brake

F1

3.16A

Supply voltage up to max. 3 * 500V AC
Operating range: 3*80V AC - 3*500V AC; 45 - 65 Hz.

Typical AC mains: 400V

±

10%; 460V

±

10%;480V

±

5%

!

Layout of contactors for the power supply:
Capacity according to device performance: Application group AC3

Switching on the operating voltage for a second time:
Before switching on the operating voltage for a second time, you must wait for at
least 2.5 minutes otherwise you may overload the condenser load resistance.

Control voltage

!

21.6V to 26.4V DC

Ripple: < 1V

SS

fuse protection: max. 16A

Mains supply fuse protection

62A K circuit breaker or suitable Neozed conventional fuse.

Regeneration mode

!

Storable energy: 3450µF/542 Ws

!

External ballast resistance: 10

/2 kW

For the external ballast resistors available, please see Page 193.

7.4.2 Installation and dimensions of COMPAX 35XXM

390

340

86

65

65

218

190

45

0

36

3

190

43

0

10 14

38

Digital

COMPAX-M

X5

X7

IN

OUT

X19

Control

H1

X6

In pu t

O utp ut

S ta tus

Value

+

-

E n ter

Re ady

E r ro r

R S 23 2

Test

C o n tr ol

X8

X1 0

X9

X1 1

N u m b er

Fastening with 4 M6 hex-socket head screws.

Plan view

Specific technical
data

Note!

Advertising