Interfaces

Digital inputs and outputs

149

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

Input I5

Starts the program data record at WAIT

START, after Power On and after STOP.

Performs the next data records (commands)

before the next WAIT

START command, an

END instruction or a STOP or BREAK signal.

O4 "Ready for start" is reset.

Once a positioning process has been

interrupted by STOP (I6="1"), the process can
be continued, when START (I5="1") is
present, using a descending flank at STOP
(I6="0").

Input I6

The positioning process is interrupted using "1" and the axis is stopped in a

controlled manner.

O4 "Ready for start" and O6 "Idle after stop" ="1".

A new start command is required to complete the positioning process. When

START is present, resetting the STOP signal is sufficient (I6="0").

Input SHIFT I2

Finds the machine zero point (when using reversing initiators: process velocity:

P3 - the direction of the search can be determined using the P3 sign ; ramp
time: P7).

Once the MZ is reached, output O3 "Machine zero approached" is set. This

remains set until another "Find MZ" order is issued.

Output O5 "Programmed position reached" ="0".

The data record indicator is reset to N001.

Reference travel, prompted by the digital inputs, interrupts a positioning

command specified by the interfaces (POSA, POSR, LOOP).

Input SHIFT I3

The axis travels to the real zero point (process velocity: P4; ramp time: P8).

O4 "Ready for start" ="0" until RZ is reached.

Output O5 "Programmed position reached" ="0", and once real zero is

approached ="1".

Data record indicator is reset to N001.

In continuous mode the axis does not move; the data record indicator is set to

N001.

Input SHIFT I4

The current position of the axis is used as the reference point (real zero) for all

positioning instructions; i.e. P1 is modified.

The data record indicator is set to 1.

The real zero is stored protected against power failure.

O4 "Ready for start" is not modified.

The teach in function can be switched off using P211.

The function does not operate in continuous mode.

START

Temporal course of a start sequence:

O4 (ready for start) = "1" ?

yes

no

I5 (start signal) = "1"

O4 (ready for start) = "0" ?

I5 (start signal) = "0"

yes

no

drive to MN

Note!

STOP

Find MZ

Approach RZ

Teach in real
zero (Teach Z)

Advertising