Operating instructions, Compax-m / -s – Parker Products COMPAX-M /-S (L) User Manual

Page 130

Advertising
background image

Operating Instructions

COMPAX-M / -S

Optimization parameters

130

Advance speed control
Nominal value: 100% Range: 0%...500%

t

Driving
fault,
current

t

1

2

3

4

reference
value,
actual
value

Advance speed and acceleration control
Nominal value: 100% Range: 0%...500%

t

Driving
fault,
current

t

1

2

3

4

reference
value,
actual
value

Advance speed, acceleration and power control
Nominal value: 100% Range: 0%...500%

t

Driving
fault,
current

t

2

1

3

4

reference
value,
actual
value

The advance reverse control can be engaged to increase optimization of guide
characteristics and reduce dynamic lag error by using P69. Nominal value: 100%
Range: 0 ... 500% default value: 0; applies to VP

P25: Advance
speed control:

P26: Advance
acceleration
control

P70: Advance
power control

Advance reverse
control

1: Nominal speed value
2: Actual speed value
3: Motor power
4: Lag error

1: Nominal speed value
2: Actual speed value
3: Motor power
4: Lag error

1: Nominal speed value
2: Actual speed value
3: Motor power
4: Lag error

Advertising