Operating instructions, Compax-m / -s – Parker Products COMPAX-M /-S (L) User Manual

Page 150

Advertising
background image

Operating Instructions

COMPAX-M / -S

Digital inputs and outputs

150

Input SHIFT I5

When P211="3", the data record indicator is set to 1 using "Shift I5".

P211 Function

= 0

The functions I1 + I4, Teach N, I1 + I5 and Teach Z are enabled.

= 1

Teach Z is blocked; the data record indicator is set to 1 using I1 + I4 or
"Teach Z".

= 2

Teach N is blocked; the data record indicator is set to 1 using I1 + I5 or
"Teach N". (Teach Z is enabled)

= 3

The functions Teach N and Teach Z are blocked. With I1 + I4, Teach N, I1
+ I5 or Teach Z, the data record indicator is set to 1.

Input SHIFT I6

The positioning process is interrupted, the axis is stopped.

O4 "Ready for start" is reset.

The program data record is not ended after a start. The next data record applies.

During an EMERGENCY STOP, the data record is interrupted, the drive brakes

with braking time P10; after P10, the motor is switched off.

The interrupted data record is continued to its completion after acknowledgment

and START.

Transfers that trigger functions are described. All other transfers and statuses do
not trigger any functions.

Function

I1

I2

I3

I4

I5

I6

Start Hand+

0

0

0

0

0

End Hand+

X

X

X

X

0

Start Hand-

0

0

0

0

0

End Hand-

X

X

X

X

0

QUIT

0

0

0

0

0

START

0

0

0

0

0

START

0

0

0

0

1

STOP

0

X

X

X

X

1

Find MZ

1

0

0

0

0

Approach RZ

1

0

0

0

0

Teach - RZ

1

0

0

0

0

SHIFT I5

1

0

0

0

0

BREAK

1

X

X

X

X

1

Input I11

Function is switched on by P232="4" (see Page 136).

I11="0":External position adjustment switched off (reaction time approx. 5 ms).

I11="1":External position adjustment switched on.

P211: blocking
and modifying
teach in functions

Break

EMERGENCY
STOP

Triggering

functions:

Activate
position
adjustment

Advertising