Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

7.9.2 Digital inputs and outputs for COMPAX 1000SL

COMPAX 1000SL physically has 8 digital inputs and 8 digital outputs which are
assigned to connector X19.
COMPAX internally has 16 logic inputs and 16 logic outputs, some of which have
functions assigned to them. This means that not all logic inputs and outputs can be
interrogated or output via physical inputs and outputs. In order to enable flexible
assignment, a matrix was created for input and output assignment respectively
which makes it possible to assign the logic inputs and outputs to any of the
physical inputs and outputs. The matrices for allocation are realized via parameters
P156 to P160 (see Page 140). The assignment described below applies to
COMPAX 1000SL (standard unit) with default settings for parameters P156 to
P160.

X19
Pin

Assign-
ment

Meaning for COMPAX 1000SL standard unit and default
settings for parameters P156 to P160

1. GND
2. Input

SHIFT

="0"

="1"

3. Input

Manual+

Find machine zero

4. Input

Hand–

Approach real zero

5. Input

Quit

Teach real zero

6. Input

START

-

7. Input

Stop (interrupts
data record)

Break (breaks off
data record)

8. Input

Freely assignable in the standard unit. (I12)

9. Input

Freely assignable in the standard unit. (I16)

10. reserved
11. Emergen

cy stop

Emergency stop input (emergency stop is triggered
by voltage < 15V DC)

12. Enable

COMPAX 1000SL is enabled by 24V DC at X19/12

13. Override

Input voltage 0 - +5V.

14. GND
15. Output

="1":No fault
="0":errors E1 ... E58; the drive does not accept

any positioning commands.

After "Power on" O1 remains at "0" until after the
self test.

16. Output

="1":No warning
="0":Error

E58

17. Output

Machine zero has been approached

18. Output

Ready for start

19. Output

Programmed set point reached

20. Output

Idle after stop

21. Output

Freely assignable in the standard unit. (O7)

22. Output

Freely assignable in the standard unit. (O8)

23. 24VDC

Load < 50mA

24. Ready P

Ready contact for building a safety chain

25 pin Sub-D
socket strip
screw
connection
UNC4-40

14

25

1

13

25. Ready S

Ready contact for building a safety chain

Note the assignment for unit variants and for special functions.