Interfaces, Start-up manual, 9 interfaces – Parker Products COMPAX-M /-S (L) User Manual

Page 52: Compax-m / -s

Advertising
background image

Start-up manual

COMPAX-M / -S

Digital inputs and outputs (excluding COMPAX 1000SL)

52

7.9 Interfaces

7.9.1 Digital inputs and outputs (excluding COMPAX 1000SL)

The inputs and outputs have PLC voltage levels (High signal = 24V DC)

X8
Pin

Assignment

Meaning

1. Input

I1

SHIFT

="0"

="1"

2. Input

I2

Manual+

Find machine zero

3. Input

I3

Manual–

Approach real zero

4. Input

I4

Quit

Teach real zero

5. Input

I5

Start

-

6. Input

I6

Stop (interrupt
data record)

Break (breaks off
data record)

7. Input

I7

8. Input

I8

Freely assignable in the standard unit.

9. Output

O1

="1":No fault
="0":errors E1 ... E58; the drive does not

accept any positioning commands.

After "Power on" O1 remains at "0" until after
the self test.

10. Output

O2

="1":No warning
="0":error

E58

11. Output

O3

Machine zero has been approached

12. Output

O4

Ready for start

13. Output

O5

Programmed set point reached

14. Output

O6

Idle after stop

15. Output

O7

Connectors:
Phoenix
MC1.5/16-ST-
3.81

4
5
6
7
8
9

101
1

12

131
4

151
6

123

16. Output

O8

Freely assignable in the standard unit.

The "SHIFT signal" (I1) must be assigned before or at the same time as the
relevant input.

X10
Pin

Assignment

Meaning

1. Input

I9

2. Input

I10

3. Input

I11

4. Input

I12

5. Input

I13

6. Input

I14

7. Input

I15

8. Input

I16

9. Output

O9

10. Output

O10

11. Output

O11

12. Output

O12

13. Output

O13

14. Output

O14

15. Output

O15

Connector:
Phoenix
MC1.5/16-ST-
3.81

4
5
6
7
8
9

101
1

12

131
4

151
6

123

16. Output

O16

Freely assignable in the standard unit.

Note the assignment for unit variants and for special functions.

Assignment of X8
(Input/Output)

Assignment of
X10 (Input/Output)