Operating Instructions

COMPAX-M / -S

Configuration parameters

76

P94 ="2"
The mechanics are subject to minimum load when using the smooth function.

t

V

t

a , M

0

0

ta

1,9

Current required: 1.9 times

P94="3"
Gentle running in to the nominal value; overswings are prevented.

t

V

t

a , M

0

0

ta

2,0

Current required: 2 times

ta: Ramp time (can be set using the command "ACCEL", see Page 97)
v:

Speed:

a:

Acceleration.

M:

acceleration torque

Transfer of P94

Modifications to P94 become effective from the next move command.

For the functions:

stop after passing a limit switch and

synchronous stop via I13 (see Page 151).

the ramp type only becomes valid with VC

Parameter P80: select drive type
Various data are required for additional configuration depending on the drive type
selected. This modifies the assignment of the parameters P81 - P85.
Continue configuration with the drive type selected.

P80=2:

Length of spindle
Range: 0 ... 5000mm

Diameter of spindle
Range: 8 ... 80mm

Pitch per spindle revolution.
Range: 1 ... 400mm

smooth

quadratic

Exception:

Drive type:

Spindle drive:

P81: length

P82: diameter

P83: Pitch