COMPAX-M / -S

Machine zero mode

82

Additional machine zero modes

The machine zero modes described below are all used without reversing initiators.
The search direction and the evaluated initiator side are influenced as follows with
these machine zero modes:
P213: defines the start search direction and (if there is an initiator fitted) the initiator

flank of the machine zero initiator which is being evaluated; i.e. the side from
which the initiator is approached

P3:

no influence in the start search direction during find machine zero.

P215: no influence on find machine zero.
P29: shifts the actual machine zero in the direction of the clockwise rotating motor

(see below).

P212 ="1"

Find machine zero

Application

P213

="0
"

clockwise rotating motor

resolver zero pulse

MN-Ini.

P29 = 270°- 360°

P29 = 0° - 270°

actual machine zero

signal of MZ
initiators

Standard machine
zero mode for linear
movements

P213="1"

clockwise rotating motor

resolver zero pulse

MN-Ini

actual machine zero

P29 = 100°- 360°

P29 = 0°-100°

signal of MZ initiators

Machine zero
equals external
initiator &
resolver zero