Appendix

COMPAX-M/S

COMPAX standard parameters

220

No.

Meaning

Unit

Minimum
value

Default
value

Maximum
value

Valid
from...

P216 Limit switch position E1 is approached when

...

"0": motor turns clockwise
"1": motor turns anti-clockwise

immediat.

P217 Limit switch mode

"0": without limit switch
"1": with limit switch

(do not find during MZ)

"3": with limit switch

(find during MZ)

"5": with limit switch (without pos. locking)

immediat.

P218 Error cutout

Default value: P218=0 (E57 active)

Bit 0 ="0" E57 active ="1" E57 switched
off

immediat.

P219 Emergency stop

input on COMPAX-
M / Synchronous
STOP on COMPAX
XX00

=0

no evaluation of emergency stop input on COMPAX-M

=7

emergency stop input on COMPAX-M active

=128 synchronous STOP on COMPAX XX0X without evaluation of

emergency stop input on COMPAX-M

=135 synchronous STOP on COMPAX XX0X with evaluation of

emergency stop input on COMPAX-M

VP

P221 Freely assign

standard inputs I1
...I8 with "1"

Input (valency) [Bit No.]:

E1 (1) [1]

••••

E2 (2) [2]

••••

E3 (4) [3]

••••

E4 (8) [4]

E5 (16) [5]

••••

E6 (32) [6]

••••

E6 (64) [7]

••••

E6 (128) [8]

P221 = sum of valencies of all required free inputs.
The control functions are assigned to the fieldbus with the bit set (I17 ... I24)

immedia-

tely

P222 Freely assign

standard inputs I9
...I16 with "1"

Input (valency) [Bit No.]:

I9 (1) [1]

••••

I10 (2) [2]

••••

I11 (4) [3]

••••

I12 (8) [4]

I13 (16)[5]

••••

I14 (32)[6]

••••

I15 (64)[7]

••••

I16 (128)[8]

P222 = sum of valencies of all required free inputs.
The control functions are assigned to the fieldbus with the bit set (I25 ... I32)

immedia-

tely

P223 Assign outputs O1 -

O8 to the OUTPUT
WORD command
with a "1"

Output (valency) [Bit No.]:

O1 (1) [1]

••••

O2 (2) [2]

••••

O3 (4) [3]

••••

O4 (8) [4]

O5 (16) [5]

••••

O6 (32) [6]

••••

O7 (64) [7]

••••

O8 (128) [8]

P223 = sum of valencies of the OUTPUT WORD outputs

immedia-

tely

P224 Assign outputs O9

- O16 to the
OUTPUT WORD

62

command with "1"

Output (valency) [Bit No.]:

O9 (1) [1]

••••

O10 (2) [2]

••••

O11 (4) [3]

••••

O12 (8) [4]

O13 (16)[5]

••••

O14 (32)[6]

••••

O15 (64)[7]

••••

O16 (128) [8]

P224 = sum of valencies of the OUTPUT WORD outputs

immedia-

tely

P225 Freely assign

standard outputs
with "1"

Output (valency) [Bit No.]:

O1 (1) [1]

••••

O2 (2) [2]

••••

O3 (4) [3]

O4 (8) [4]

••••

O5 (16) [5]

••••

O6 (32) [6]

P225 = sum of valencies of all required free outputs.

immedia-

tely

P227 Assign special

functions to
outputs

Bit 1

63

="0": O2 is assigned the default function (=no warning).

Bit 1="1":

O2 is assigned the "Idle monitor" function.

Bit 4="0":

O5 is assigned the default function (position reached with
evaluation of P14)

Bit 4="1":

O5 is assigned with the "O5 toggles when position
reached" function.

immedia-

tely

P229 Speed threshold for "Idle display" function (only

switched on if P227 bit 1="1")

0

0

255

VP

P232 Function I11

=0: I11 can be freely assigned
With external position adjustment switched on (P75>0):
=4: I11 switches the external position adjustment

(I11="0": off and I11="1": switched on)

COMPAX 1060/70SL: With analogue

±

10V – interface

=4: I11 has the function "Enable analogue input

(

I11="0": Setpoint=0 I11="1": analogue input active)

VP

P233 Setting the optimization display S13

1...255

immedia-

tely

P234 Setting the optimization display S14

1...255

immedia-

tely

62

OUTPUT WORD – command is available with bus systems.

63

Bit-counting starts with Bit 0.