Appendix

COMPAX-M/S

Hand-held terminal

208

Unit designations

Designation:

Status
No.

Meaning

Software version

S31

Designation of software version.

Software date

S32

Date when program was created.

Order

S33

Order number (6 digits)

Order&part (10 digits) is

Part

S34

Serial four-digit number

a unique unit no.

Version

S35

Not assigned.

IFM identification

S36

Date, version and designation of the bus option (hardware module)

Unit designation

S37

COMPAX P1XXM: 80

COMPAX P1XXM N1: 90

COMPAX 02XXM: 85

COMPAX 05XXM: 170

COMPAX 15XXM: 500

COMPAX 35XXM: 1000

COMPAX 25XXS: 4

COMPAX 45XXS: 6

COMPAX 85XXS: 5

COMPAX 10XXSL: 20

Unit family

S38

E.g. "00": COMPAX XX00

"30": COMPAX XX30 ...

Unit

S39

"0": COMPAX E "1": COMPAX-M

"2": COMPAX-S

"4": COMPAX-SL

"9": SV drive

Status values

S40

Number of status values present

Special COMPAX XX00 status values

Designation:

Status No.

Unit

Meaning

Speed

S41

%

External velocity when using the SPEED SYNC command.

Encoder position

S42

P90 External position when using external position localization.

Measuring error

S47

P90 During external position localization: difference between resolver

position and encoder position.

Current nominal
value

S49

P90 Current internal nominal value (output of nominal value setter and

track nominal value directly specified by HEDA).

Meaning of status bits

The status bits are not relevant for normal operation; they must not be used for control purposes. They do
provide accurate error analysis if you contact HAUSER in case of problems. - The bits are counted from the
left to the right.

S23, S24, S25

Bit

Drive status (S23)

Switch status (S24)

Limits status (S25)

-1111------1111-

-111--111--11042--

-11--11--11--11-

1

(left)

Not assigned

Not assigned

Not assigned

2

Drive not at standstill

Override function

reserved

3

Deceleration phase

Limit switch 2 (-) activated

reserved

4

Acceleration phase

Limit switch 1 (+) activated

Not assigned

5

Speed reached (speed regulation)

Not assigned

Not assigned

6

Not assigned

Not assigned

No motor current

7

Not assigned

Zero initiator activated

8

Not assigned

reserved

Not assigned

9

Not assigned

reserved

Not assigned

10

Not assigned

Not assigned

Position not OK.

11

Not assigned

Not assigned

Tracking error

12

Speed reached (positioning)

reserved

Not assigned

13

Positioning process complete

Do not change data record
(emergency stop)

Not assigned

14

Drive blocked

reserved

Speed limit reached

15

Machine zero reference present

Not assigned

Current limit reached

16

(right)

Not assigned

Not assigned

Not assigned

42