10.3 COMPAX parameter

10.3.1 VP parameter

46

can be modified "On Line"

VP parameters can be modified and transferred and the password specified in any COMPAX
operating mode.

Note!

Note the following points.
1. Processor load

When parameters are being validated using the "VP" command, the response time and
command execution time is temporarily extended due to the increased computing time.
e.g. when the parameters are transferred, a "Stop signal" is recognized after a short delay.
Typical delay times would be:
range of parameters:

P1 ... P79: approx. 0.5 ms per parameter.

>P79:

approx. 20 ms.

2. Modifying the controller setting

When modifying the controller setting via parameters P23, P24, P25, P26, P27 or P70,
comparison processes may occur. These may be detected as short axis readjustments.
Therefore: only modify parameters in small steps when the axis is active.

3. Area of application

This extension to the function is used for the start-up and for optimizing the axis.
It is not intended for the implementation of control tasks.

Please note: The axis must be switched off if modified VP parameters are to be transferred
(e.g. via OUTPUT O0=1).

10.3.2 COMPAX standard parameters

Parameter groups:
Control parameters

P40 ... P49

Limitations

P11 ... P16

Bus parameters

P135 ... P142; P190 ... P196

D/A monitor, status monitor S15

P71 ... P74, P76, P77, P182

Inputs/outputs: assignment / meaning

P18, P211, P221 ... P225, P227, P245, P246

Define encoder interfaces(option)

P75, P98, P143, P144, P146, P232

Substitution and specification values:

P1 ... P10

HEDA

P181, P184 ... P188, P243, P247 ... P250

Configuration parameters

P80 ... P85, P88, P90, P92, P93, P98

Mark reference

P35, P37, P38, P39

Define mechanical reference system

P29, P206, P212 ... P217,

Motor parameters

P100 ... P133

Optimization parameters, optimization display

P21 ... P27, P50, P67 ... P70, P94, P151, P233, P234

Parameters of software variants

P30 ... P39

RS232

P19, P20

Other parameters

P17, P218, P219, P229

PLC data interface

P18

Parameters not described here are reserved.

46

VP means "Valid Parameter" and is a COMPAX command with which COMPAX accepts a modified

parameter from a specific parameter group. The VP parameters are marked in the following parameter