Interfaces – Parker Products COMPAX-M /-S (L) User Manual

Page 139

Advertising
background image

Interfaces

Digital inputs and outputs

139

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

Output

Assignment

O1 (X8/9; X19/x)

="1":No fault
="0":errors E1 ... E58; the drive does not accept any

positioning commands.

After "Power on" O1 remains at "0" until after the self test.

O2 (X8/10; X19/x)

="1":No warning
="0":error

E58

O3 (X8/11; X19/x)

Machine zero has been approached

O4 (X8/12; X19/x)

Ready for start

O5 (X8/13; X19/x)

Programmed nominal position reached

O6 (X8/14; X19/x)

Idle after stop

O7 (X8/15; X19/x)

Freely assignable in the standard unit.

O8 (X8/16; X19/x)

Freely assignable in the standard unit.

O9 (X10/9; X19/x)

Freely assignable in the standard unit.

O10 (X10/10; X19/x)

Freely assignable in the standard unit.

O11 (X10/11; X19/x)

Freely assignable in the standard unit.

O12 (X10/12; X19/x)

Freely assignable in the standard unit.

O13 (X10/13; X19/x)

Freely assignable in the standard unit.

O14 (X10/14; X19/x)

Freely assignable in the standard unit.

O15 (X10/15; X19/x)

Freely assignable in the standard unit.

O16 (X10/16; X19/x)

For "0": mark disappears after max. feed length

32

The assignment of outputs on X19 applies only to COMPAX 1000SL.

32

Only assigned if the mark reference is activated (P35=1).