Synchronous stop using i13, Interfaces, 6 synchronous stop using i13 – Parker Products COMPAX-M /-S (L) User Manual

Page 151: Fast start synchronous stop

Advertising
background image

Interfaces

Digital inputs and outputs

151

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

Input I15

Special START input

Input for fast and defined starting of positioning process.

The "Fast start" function is switched on using P18=2 or 3 (when using P18=3, the

PLC data interface is also switched on).

When I15="0", all positioning processes (POSA, POSR) are blocked.

When I15="1", positioning processes are started. I15 has no influence during a

positioning process.

A positioning process interrupted with STOP is continued using START (I5="1")

and "Fast START" (I15="1").

The reaction time of I15 before the start of the positioning process is 1.5 ms.

I15 has no effect in speed control mode.

Note!

The START signal (I5) is not replaced by I15; after STOP, a START

signal (I5) is required to start the program and for WAIT START.

8.6.1.6 Synchronous STOP using I13

I13 in the standard model (COMPAX XX00) provides a STOP function with which
you can stop and idle multiple COMPAX units simultaneously, regardless of the
current speed.

P219=128 or 135 enables the synchronous stop via I13 (P219 bit 7

36

=1).

I13="1": Normal mode
I13="0": Synchronous STOP is activated.
After I13="0"

the drive is stopped using P10 as the absolute ramp time and

the ramp type selected via P94

37

.

Error message E08 is output,

O1 is set to 0 and

the ready contact is opened.

While I13=0, any further positioning attempts are negatively acknowledged with
E08. No negative acknowledgment comes from HEDA.

Synchronous STOP function using I13 is only available on the standard unit
(COMPAX XX00).

Stop using I6

Stop using I13

2...5ms

60%

100%

t

t

P10

STOP
(I6)

The same

brake ramp

Speed
COMPAX 1

Speed
COMPAX 2

<1,1ms

STOP
(I13)

Brake ramp

P10 (absolute)

Speed
COMPAX 1

Speed
COMPAX 2

P10

Using I13 for stop bring both axes to a stop simultaneously.

36

Bit counting begins with bit 0.

37

A modified ramp time is used after "VC" for the "Synchronous stop via I13"

function.

Fast start

Synchronous
STOP:

Diagram: