Compax-m unit features, Connector and terminal assignment, 2 compax-m unit features – Parker Products COMPAX-M /-S (L) User Manual

Page 17: 1 connector and terminal assignment, Connector and terminal assignment 17

Advertising
background image

COMPAX-M unit features

Connector and terminal assignment

17

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

7.2 COMPAX-M

unit

features

7.2.1 Connector and terminal assignment

X2 intermediate loop
power connections

X3 24V control voltage

X4 control- and status
signals / bus signals
or short circuit plug

X13 Encoder

COMPAX-M

X6

In p u t

O u tp u t

S ta tu s

Value

+

-

E n te r

R eady

E rro r

R S 2 3 2

Test

C o n tro l

X8

X 10

X9

X 11

N u m b e r

X1 motor

X5 control- and

status- signal

bus-signals

input

X6 RS232

X10 Input / Output

X11 Control

X8 Input

/ Output

X9 Test

X12 resolver

X14 HEDA

X16 absolute

encoder

X18 fan

X15 HEDA
X17 initiators

Before wiring up, always de-energize the unit.

Even once the mains supply has been switched off,
dangerous levels of voltage can remain in the system for
up to 5 min.

LED

Color

Meaning, when switched on

Ready

green 24V DC present and initialization complete

Error

red

COMPAX - fault (I1...E56) present.

Meaning of LEDs on

front plate

Advertising