Interfaces – Parker Products COMPAX-M /-S (L) User Manual

Page 167

Advertising
background image

Interfaces

RS232 interface

167

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

Valency: *

1

2

15

2

14

... 2

2

2

1

2

0

.

Transmission sequence, e.g.: "84 4C MSB LSB".

Negative numbers are represented in complement to two format. Creating the
complement to two:

Determine bit combination of the positive numerical value.

Negate the binary value.

Add 1.

You can generate this format from any number (as long as it has digits after the
decimal place) as follows.

Number = 450.5
1. Multiply number by 2

24

.

450.5 * 2

24

= 7 558 135 808.

2. 7 558 135 808: convert into a hexadecimal number (if necessary into an integer

first) =>0x00 01 C2 80 00 00

before decimal place, after decimal place

MSB,.... LSB, MSB,.... LSB.

3. These bytes must now be entered into the commands in the sequence

specified. The sequence of the bytes is reversed. Do not alter the sequence of
the bits.

This conversion also applies to negative numbers.

Examples of the number format of "xx xx xx xx xx xx"

Number MSB

LSB

10

00

00

0A

00

00

00

360

00

01

68

00

00

00

450,5

00

01

C2

80

00

00

-1

FF

FF

FF

00

00

00

Digits before the decimal place

Digits after the decimal place

The following string will be produced, e.g. for POSA 360.0:

"88 41 00 00 00 68 01 00"

Note:

transfer all digits!

Note:

when binary transfer is switched on, note the following.

Only create RS232 connection when participants are switched on or
when participants are enabled, the RS232 can be re-initialized by COMPAX using
Power on.

*

1

Negative numbers

*

2

Format

conversion

Example:

Start-up during

binary transfer