Compax parameter – Parker Products COMPAX-M /-S (L) User Manual

Page 213

Advertising
background image

COMPAX parameter

213

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error List:

Remark

The specified limit values refer to all parameters. Theoretical combinations are possible within these limits,
however they could cause an internal number overrun. The following limitation applies.
The travel per motor revolution must be greater than 0.01 mm or with increment unit: > 10 increments.
Travel per motor revolution:

Spindle drive: P83;

rack-and-pinion/toothed belt P82 * P83;

general drive: P83 (/1000 in mm)

List of parameters, sorted by number

No.

Meaning

Unit

Minimum
value

Default
value

Maximum
value

Valid
from...

P1

Real – zero point (distance real zero-machine
zero).

corresp.
P90

-
1 000 000

0.00

+1 000 000

immediat.

P2

Substitute for non-programmed velocity.

%

1.00

10.00

100.00

immediat.

P3

Velocity for find machine zero.

%

-100.00

10.00

100.00

immediat.

P4

Velocity for approach real zero.

%

1.00

10.00

100.00

immediat.

P5

Velocity for processing by hand.

%

1.00

10.00

100.00

immediat.

P6

Substitute value for non-programmed ramp
time.

ms

1

1000

60 000

immediat.

P7

Ramp time for approach machine zero.

ms

1

1000

60 000

immediat.

P8

Ramp time for approach point of real zero.

ms

1

1000

60 000

immediat.

P9

Ramp time for processing by hand.

ms

1

1000

60 000

immediat.

P10

Ramp time after limit switch or emergency stop
is activated.

ms

1

250

60 000

immediat.

P11

Max. positive position referenced to machine
zero.

corresp.
P90

P12

+4 000 000.0
0

+4 000 000.00

VP

P12

Max. negative position referenced to machine
zero.

corresp.
P90

-
4 000 000.00

-
4 000 000.00

P11

VP

P13

Max. permitted lag tolerance (error E10 is
triggered when exceeded); E10 & E49 are
switched off with specification "0".

corresp.

P90

or % of

P104

47

0

10.00

4 000 000.0
0

VP

"0"

immediat.

P14

Max. permitted positioning zone (applies for
message O5 : "Position reached")

corresp.

P90

or % of

P104

48

0.00

1.00

4 000.00

VP

P15

Max. permitted velocity

%

0.00

100.00

100.00

49

VP

P16

Max. permissible torque

% of
P105

0

200

300

VP

P17

Engine brake lag

ms

0

0

4000

VP

P18

PLC data interface
Fast start via I15
Fast start via HEDA
Note!
Settings with bit 1 and bit 3 are only permitted
in COMPAX XX00.

Bit 0

50

=0 without PLC data interface

=1 with PLC data interface

Bit 1 =0 fast start via I15 not active

=1 fast start via I15 active

Bit 3 =0 no fast start via HEDA

=1 fast start via HEDA active

only permitted with P18 when bit 1=1!

VP

P19

RS232 Baud rate

Bit/s

4800

9600

51

9600

Power on

47

In speed control mode in % of nominal speed (P104), otherwise corresponds to P90

48

In speed control mode in % of nominal speed (P104), otherwise corresponds to P90

49

For asynchronous motors, the maximum permitted velocity may be up to 300% of the nominal velocity.

50

Bit counting begins at bit 0.

51

By simultaneously pressing the three front plate keys when switching on, the baud rate is set to 9600.

With COMPAX 1000SL, the baud rate is always set to 9600.

Advertising