Machine zero mode, Operating instructions, Compax-m / -s – Parker Products COMPAX-M /-S (L) User Manual

Page 80: 7 machine zero mode

Advertising
background image

Operating Instructions

COMPAX-M / -S

Machine zero mode

80

8.2.7 Machine zero mode

P212: setting the machine zero mode

="0": MZ equals external initiator rounded with resolver zero & machine zero travel

using 2 reversing initiators.

="1": MZ equals external initiator rounded with resolver zero.
="3": MZ equals external zero pulse

*

="4": MZ equals external initiator rounded with the external zero pulse.

*

="5": MZ equals resolver zero
="6": reserved
="7": MZ equals external initiator (without resolver zero).
="8": MZ equals a limit switch
="10": MZ teach
="11": Machine zero - initiator (without resolver zero) with 2 reversing initiators

P212 becomes valid immediately after a modification.

*

P212=3 & P212=4 is only permitted for COMPAX XX00 and COMPAX XX30.

Function of the machine zero mode

P212 ="0"

Start search direction / initiator side

Application

P213: defines the initiator flank of the machine zero

initiator that is being evaluated; i.e. the side
from which the initiator is approached.

P3:

the prefix defines the start search direction.

P215: influences the start search direction during

find machine zero.

P29: shifts the actual machine zero in the direction

of the clockwise rotating motor.

P216: sets the limit switch position

(must also then be set if there are no
configured limit switches (P217=0)

Linear movements

P215="0": the motor rotates clockwise when traveling in the positive direction; i.e.

the positive end in the diagram is on the right-hand side.

P212="0": operating mode with reversing initiators; i.e. with 3 initiators.
P217="0": operating mode without end initiators. I1 and I2 act as reversing

initiators during "Find machine zero".

P216="0": the I1 initiator is started by the clockwise rotating motor.
P3 = positive (when P3 = negative, reverses start search direction)

E2

MN

E1

gear doesn`t change
the direction

direction "clockwise rotating motor"

Overview:

Machine zero
equals external
initiator &
resolver zero / 2
reversing
initiators.

Example of a
reference system
definition

Advertising