Connector assignment compax 1000sl (overview), Start-up manual compax-m / s – Parker Products COMPAX-M /-S (L) User Manual

Page 42

Advertising
background image

Start-up manual

COMPAX-M / S

42

Mating connectors for X1,..X4 from Phoenix are included with the following type
designations:
X1: MSTB2.5/6/STF-5.08 (with screw connection)
X2: MSTB2.5/3/ST-5.08 (without screw connection)
X3: MSTB2.5/2/ST-5.08 (without screw connection)
X4: MSTB2.5/3/STF-5.08 (with screw connection)
You can acquire Phoenix housings for these connectors and these can be used
once adapted to our cables. Designation: KGG-MSTB2.5/(pin number).

7.7.2 Connector assignment COMPAX 1000SL (overview)

X12/1

housin

g

X12/2

+8V

X12/3

NC

X12/4

REF

-

X12/5

SIN-

X12/6

NC

X12/7

GND

X12/8

ST

+

X12/9

+5 V

X12/1

0

TE

M

P

X12/1

1

COS-

X12/1

2

COS+

X12/1

3

SIN+

X12/1

4

REF

+

X12/1

5

ST

-

X12: resolver / SinCos©

X13/1

housin

g

X13/2

NC

X13/3

NC

X13/4

A

2

an

al

og

X13/5

N1

X13/6

B1

X13/7

A1

X13/8

+5V

X13/9

NC

X13/1

0

NC

X13/1

1

A2/ anal

og

X13/1

2

N1

/

X13/1

3

B1/

X13/1

4

A1/

X13/1

5

GND

X1/2

V

X2/1

X2/2

X2/3

X3/1

+24 V

X3/2

0V

X4/1

B+

X4/2

B-

X4/3

PE

X6/2

RxD

X6/3

TxD

X6/4

DTR

X6/5

GND

X6/6

DSR

X6/7

RTS

X6/8

CTS

X6/9

+5V

L

N

PE

X1/1

U

X1/3

W

X1/4

PE

X1/5

Br+

X1/6

Br-

X1:
motor
brake

X2:
Ac supply

X3:
control
voltage

X4:
braking
resis-
tance

X6:
RS232

X13: encoder

X19/1

GND

X19/2

Input

X19/10
X19/11 emerg.-Stop

X19/12 enable

X19/13 Override

X19/14 GND

X19/15 Output

X19/16 Output

X19:
In- and
output/
Emergency
stop/
enable/
override/
stand by

X19/17 Output

X19/18 Output

X19/19 Output

X19/20 Output

X19/21 Output

X19/22 Output

X19/23 24V

X19/24 stand by P

X19/25 stand by S

X19/3

Input

X19/4

Input

X19/5

Input

X19/6

Input

X19/7

Input

X19/8

Input

X19/9

Input

X14(15)/1

NC

X17/1

DA-channel 2

X17/2

DA-channel 3

X17/3

shield

X17/4

GND 24V

X17/5

+24V

X17/6

GND

X17/7

Sig.MN

X17/8

Sig. E2

X17/9

Sig. E1

X14(15)/2

RxC

X14(15)/3

TxC

X14(15)/4

RxD

X14(15)/5

TxD

X14(15)/6

RxC/

X14(15)/7

TxC/

X14(15)/8

RxD/

X14(15)/9

TxD/

X17:
DA-monitor
initiators

X14/X15:
HEDA

X5: bus systems input

Assignment depends on
the bus system

X7: bus systems output

Assignment depends on
the bus system

The assignment of X12 does not apply for the S3 option.

Mating connectors

X1, X2, X3 and X4

Bridges for test oper

a

tion

Advertising