Compax parameter – Parker Products COMPAX-M /-S (L) User Manual

Page 219

Advertising
background image

COMPAX parameter

219

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error List:

No.

Meaning

Unit

Minimum
value

Default
value

Maximum
value

Valid
from...

P184 Selection parameters for HEDA – process value

(master)
Default value: P184=0

40: encoder position
42: internal time base
43: scaled master position
44: nominal pos. value in resolver increm.
45: actual pos. value in resolver increments
46: differentiated resolver position

VP

P185 – P187 HEDA – parameter
P188 Selection parameters for HEDA – process value

(slave)
Default value: P188=0

40: encoder coupling for encoder input

signals (P184=40)

140: encoder coupling for other input

signals (P184

40)

42: internal time base
43: scaled master position

VP

P191 – P196 Bus – parameter
P197 Order (status S33)

"Read only" – parameter

P198 Part (status S34)

"Read only" – parameter

P202 With machine zero mode P212="8": Distance

machine zero – limit switch (setting "0"
corresponds to "3")

motor

revol.

3

0

255

VP

P206 Enables the absolute value sensor input / the

reset function of option S2 / absolute value
sensor

="1": absolute value sensor input enabled or

reset function switched on

(S2 opt.)

= "2": absolute value sensor enabled

VP

P211 Disable and modify the Teach In – function

Also:
enable final stage with OUTPUT O0="0" without
lag (Bit 2="1")

"0" The teach data record and teach real

zero functions are enabled.

"1" Teach in real zero is blocked, data

record indicator is set to 1 using I1 + I4 .

"2" Teach in set is blocked, data record

indicator is set to 1 using I1 + I5 .
(Teach real zero is enabled)

"3" The teach data record and teach in real

zero functions are blocked. With I1 + I4,
Teach N or I1 + I5, the data record
indicator is set to 1.

"4...7": The final stage is enabled with

OUTPUT O0="0" without lag (P. 123)

immedia-

tely

P212 Machine – zero – mode

Settings "3" and "4" with COMPAX XX00 and
COMPAX XX30 only

"0": MZ equals external initiator & resolver

zero / 2 reversing initiators.

"1": MZ equals external initiator & resolver

zero.

"3": MZ equals external zero pulse
"4": MZ equals external initiator & external

zero pulse.

"5": MZ equals resolver zero
"6": reserved
"7": MZ equals external initiator (without

resolver zero).

"8": MZ equals limit switch
"10": teaches machine zero
"11": MZ equals initiator (without resolver

zero) / 2 reversing initiators.

immedia-

tely

P213 Machine zero direction

"0": to the right "1": to the left

VP

P214 Encoder direction

"0": positive direction when encoder is

turning clockwise.

"1": positive direction when encoder is

turning anti-clockwise.

VP

P215 Direction of rotation

"0": motor to the right "1": motor to the left

VP