Compax 1000sl unit characteristics, Start-up manual compax-m / s, Caution – Parker Products COMPAX-M /-S (L) User Manual

Page 40: Pe – terminal: led display, At least 2.5mm

Advertising
background image

Start-up manual

COMPAX-M / S

40

7.7

COMPAX 1000SL Unit characteristics

7.7.1 Connector and terminal assignment for COMPAX 1000SL

Fie

ldb

us

In

E

n

c

ode

r

Inp

u

t /

O

u

tp

ut

Re

s

o

lve

r

Fie

ldb

us

O

u

t

Lim

it S

w

itch

24

V

DC

R

Du

m

p

H2

H1

RS2

3

2

X6

X5

X13

X12

X17

X19

X2

X1

X4

X3

X14

X

15

HED

A

O

u

t

H

ED

A

In

Inp

u

t

+-

L1

N

P

E

UV

W

PE

+

-

Mo

tor

Brake

PE

+

-

23

0

V

A

C

COMPAX

-

S

L

X7

X13
encoder

X6 RS232

X7 OUT

X5 IN

bus
systems:

X19 in-/
output

X14/X15
HEDA

X17
initiators

X12
resolver

X3 24V DC
supply

X4 ballast
resistance

X1 motor /
motor brake

X2 230V AC
supply

PE -
connection

Before wiring up, always de-energize the unit.
Even once the mains supply has been switched off, dangerous
levels of voltage can remain in the system for up to 5 min.

When working with motors without a holding brake, the brake lines
must not be connected to COMPAX

Caution!

If the unit has no control voltage, displays will not indicate if operating
voltage is present.

at least 2.5mm

2

The following statuses are shown by the LEDs.

Status

Red LED (H2)

Green LED (H1)

24V not available

off

off

24V are switched on, boot up

on

off

Unit OFF

off

blinking

Unit error; drive switched off

on

blinking

Unit error; drive powered

on

on

Unit RUNNING

off

on

PE – terminal:

LED display

(Option)

Advertising