Diagrams, Operating instructions, Compax-m / -s – Parker Products COMPAX-M /-S (L) User Manual

Page 154: 8 diagrams

Advertising
background image

Operating Instructions

COMPAX-M / -S

Digital inputs and outputs

154

O6

O6="1" indicates that the axis is at a standstill due to a STOP (I6) or BREAK

(I1&I6).

O6 is reset when the axis moves again.

O16

Only assigned if mark reference is activated (P35=1).

With "0", the mark disappears once the maximum feed length is reached (see

Page 100)

8.6.1.8 Diagrams:

t

t

t

t

tt

tt

t

I3

Jog-

I5

Start

I6

Stop

V

O4

Ready

to Start

O5

Progr. target

pos. reached

O6

Out of action

after stop

0

0 1

2 3

4

5

6

7 8

0 COMPAX ready for new start.
1 When using START at input I5, the outputs O4 and O5 are reset. The axis moves.
2 Interruption using STOP at input I6. After idle, message at output O6 (3).
4 START using I5. Positioning process is continued.
5 Positioning process ended. Message via O4 and O5="1".
6 Manual processing of axis. O5 and O4 ="0".
7 Specification for manual processing ended. Drive decelerates.
8 Manual process ended. Drive at standstill. Ready message for output O4 is set.

Idle after stop
or break

Mark missing
after maximum
feed length

In data record
memory mode

Caption:

Advertising