Configuration via PC using "ServoManager"

Individual configuration of synchronous motors

93

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

Nominal motor speedfor

HDY motors:

P104: nominal motor speed [rpm]

EMC

n

N

[min

-1

]

U

ZW

=300V

U

ZW

=560V

32

5000

44

4400

5000

64

2800

5000

88

2000

3800

130

1400

2500

180

1800

Parameter for saturation characteristic curve:

P119

start of saturation [%]

P120: end of saturation [%]

P121: minimum stator inductivity

[%]

Flange size

P119

P120

P121

HBMR

<= 115 mm

100

280

40

>= 142 mm

70

240

40

HDY/ HJ

100

400

100

Saturation is switched off when P119 = P121 = 100% and P120 = 400%.

If the saturation is unknown, use the HDY values.

The additional parameters in the motor table should only be modified
under exceptional circumstances.

Default values of the HBMR and HDY motors:

Parameter

Standard

Meaning

Unit

P107

300

Pulse current

%

P108

3000

Pulse current time

ms

P129

0

Resolver offset

Degree

P130

"2"

Resolver frequency

P131

"2"

Resolver
amplification

P132

"2"

Position sensor

P133

65 536

Sensor dash count

Increments

For motors with holding brake.

Calculate the braking delay in P17 (for more information, see Page 123).
The parameters for Parker motors can be found in the motor catalogue (Art.
No.190-060011)

Drive type

If you initially want to operate the motor without mechanics, select:

P80=16: general drive.

P81=P82=moment of inertia of the motor.

P93=2: continuous mode.

Call up the "Parameter: Guided parameter setting" menu.
The remaining parameters are queried one after the other.

Use menu "Online: Download" to transfer the data into COMPAX and validate the

settings.

Caution!
Secure the displacement area of your system or the motor. When
switching on, a risk may be posed by incorrect configuration data.

Holding brake

with
EMC: counter EMC
n

N

: nominal speed

U

ZW

: intermediate circuit voltage

300V: with 230V AC
560V: with 3 * 400V AC