Positioning and control functions

Speed monitoring in speed control mode (P93="4")

121

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

O5="1": nominal value reached on nominal value generator and speed deviation

< P14.

If the speed deviation returns to > P14, O5="0" is set.
Can be adjusted using: P227 bit 4 ="0" (default setting)

P14

speed

P13

t

t

O5

Programmed
demanded
speed

Actual value

If the actual value moves outside P13, error E10 is triggered.

O5="1": nominal value on nominal value generator reached (independent of P14

asP14 is set as a very large value)
Can be adjusted using: P227 bit 4

29

="0"

(default setting)

Speed

O5

Actual value

Programmed
demanded
speed

29

Bit counting begins with 0.

OM2: O5 = "1":
nominal value
reached and
speed error <
P14

Example:

OM3: O5 = "1":
nominal value
reached

(independent of P14)

Example: