Fire-Lite MS-9050UDC Addressable Fire Alarm Control Panel User Manual

Page 13

Advertising
background image

MS-9050 Series Manual — P/N 52413:G 4/14/2014

13

Features and Options

Product Description

Communication Confirmation (Kissoff) LED

Touchtone/Rotary dialing

EIA-232 PC interface for local upload/download

80-character LCD display (backlit)

Real-time clock/calendar with daylight savings time control

History file with 500 event capacity

Advanced fire technology features:

Automatic drift compensation

Maintenance alert

Detector sensitivity test capability (NFPA 72 compliant)

Automatic device type-code verification

Point trouble identification

Waterflow selection per module point

Alarm verification selection per detector point

Walktest, silent or audible

PAS (Positive Alarm Sequence) per addressable detector and Pre-signal per point (NFPA 72
compliant)

Silence inhibit timer option per NAC

Autosilence timer option per NAC

Continuous, March Time, Temporal or California code for main circuit board NACs with two-
stage capability

Selectable strobe synchronization per NAC

Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote
annunciator

Auto-program (learn mode) reduces installation time. Reports two devices set to the same
address

Password and key-protected nonvolatile memory

User programmable password

Fully programmable from local keypad or optional keyboard

SLC operates up to 10,000 ft. (3,000 m) with twisted, unshielded fire wire

Compatible with Fire-Lite addressable devices (refer to the SLC Wiring Manual)

Compatible with legacy Fire-Lite 300 Series addressable devices (refer to the SLC Wiring
Manual
)

Optional 4XTMF module (conventional reverse polarity/city box transmitter)

Optional ANN-I/O LED Driver module

Optional ANN-S/PG printer interface module

Optional ANN-80 remote LCD annunciator

Optional ANN-80C remote LCD indicator (for Canadian applications)

Optional ANN-LED Annunciator Module annunciates alarm, trouble and supervisory

Optional ANN-RLED Annunciator Module annunciates alarms only

Optional ANN-RLY Form-C Relay Module

Optional ANN-LC Lite-Connect Module

Optional Dress Panel DP-51050 (a modified dress panel with the ANN-LED is included
standard with the MS-9050UDC)

Optional PRN-6F Serial Printer (requires ANN-S/PG module)

Optional PK-CD (contains PS-Tools) for local/remote upload/download of programming and
data