17-2

Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1

Chapter

Checking Temperature Status and Configuring Thresholds

You can check the temperature status and configure temperature
thresholds by using either the Web Agent or the CLI.

* Note: The temperature thresholds have been raised for the

backplane and slot 1. In high temperature climates, the
switch was frequently reaching the default temperature
thresholds. Table 6-109 lists the new default
temperature thresholds. All temperatures are measured
in degrees Celsius.

Table 6-109. New Default Temperature Thresholds

10/100
Modules

Port

Solid green,
with orange
flash

Port enabled and sending and
receiving traffic Traffic
indicated by yellow flashes.

Flashing green

Port disabled with link up.

Flashing
orange

Hardware failure.

Off

No link.

Table 6-108. Front Panel LED Display Interpretation continued

Module...

LED...

Behavior...

Indication...

Temperature
Threshold

Slot 1

Backplane

CPU
Sensor

Upper Warning

60°

60°

85°

Lower Warning

Low Warning

Shutdown Temperature

65°

65°

100°