Reported Fault

Value

Bit

Cannot start because of inconsistent database. The type of
database inconsistency is reflected in the status SR report, and in
the CD CPU dump report.

0x200 9

Too large a difference in ECAM table.

0x400

10

Heartbeat failure. Error occurs only if drive is set to abort under
heartbeat failure in a CANopen network (object 0x6007 in CAN
object dictionary is set to 2).

0x800 11

Servo drive fault. Error described according to the servo drive
fault detail bits 13 - 15 in the MF report. Refer to following table.

0x1000 12

Servo drive fault detail bit 1. Refer to following table.

0x2000

13

Servo drive fault detail bit 2. Refer to following table.

0x4000

14

Servo drive fault detail bit 3. Refer to following table.

0x8000

15

Failed to find the electrical zero of the motor in an attempt to
start it with an incremental encoder and no digital Hall sensors.
The reason may be that the applied motor current did not
suffice for moving the motor from its position.

0x10,000 16

Speed limit exceeded: VX<LL[2] or VX>HL[2].

0x20,000

17

Stack overflow - fatal exception. This may occur if the CPU was
subject to a load that it could not handle. Such a situation can
arise only due to a software bug in the drive. Use the CD
command to get the CPU dump and report to your service
center.

0x40,000 18

CPU exception - fatal exception. Something such as an attempt
to divide in zero or another fatal firmware error has occurred.
Use the CD command to get the CPU dump and report to your
service center.

0x80,000 19

Reserved. 0x100,000

20

Motor stuck - the motor is powered but is not moving according
to the definition of CL[2] and CL[3].

0x200,000 21

Position limit exceeded: PX<LL[3] or PX>HL[3] (UM=5), or
PY<LL[3] or PY>HL[3] (UM=4).

0x400,000 22

Reserved. 0x10,000,000

28

Cannot start motor.

0x20,000,000 29

Reserved. 0x80,000,000

31

Table 3-30: Reasons for Automatic Motor Shutdown