The bit descriptions of the WS[93] command are summarized in the following table.

Bit

Description/ Report status

0

The CPU did not receive a start bit within 55 msec of sending a query

message to the sensor.

1

A CRC error occurred during an attempt to select the memory sensor area

for a read/write operation.

2

A CRC error occurred during an attempt to read from the sensor memory.

3

A CRC error occurred during an attempt to write to the sensor memory.

4

CRC error during an attempt to read the sensor position.

5

A CRC error occurred during an attempt to send the sensor a reset

command.

6

A failure was detected during the sensor power up sequence initialization.

7

The sensor alarm bit is set.

Table 3-51: WS[93] Error Bit Descriptions

The bit description in WS[94] indicating EnDat sensor errors flags are summarized in the
following table.

Bit

Subject

= 0

= 1

0 Light

source OK

Failure

1 Signal

amplitude

OK

Erroneous

2 Position

value OK

Erroneous

3 Over

voltage No

Yes

4

Under voltage

No

Under Voltage supply

5

Over current

No

Yes

6

Battery

OK

Change the battery

Table 3-52: WS[94] Error Bit Descriptions

The bit description in WS[95] indicating EnDat sensor warnings flags are summarized in
the following table.

Bit

Subject

= 0

= 1

0 Frequency

collision No

Yes

1 Temperature

exceeded

No

Yes

2

Light source control reserve Not Reached

Reached

3 Battery

charge

OK Insufficient

4 Reference

point

Reached Not

reached

Table 3-53: WS[95] Error Bit Descriptions

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-158

Advertising