RL - Record Length

Purpose:
Specifies the length of the recorded data, as follows:

Number of Simultaneously
Recorded Signals

Maximum
Record Length

1 4096
2 2048
3 1365
4 1024

Table 3-39: Record Length of Simultaneously Recorded Signals

RL can specify that the signal records will be shorter than the maximum. If RL is set to a
value higher than the maximum record length (for example, RC defines three recorded
signals, but RL=2048), the recorder will still work. The length of the records, however,
will be shorter than RL. The actual size of the recorded data is returned by WI[21].

Attributes:

Type: Parameter,

Integer

Source:

Program, RS-232, CANopen

Restrictions:

Recorder inactive (RR=0 or RR=-1)

Default value:

256 (RS), Volatile

Range: [1…4096]
Unit modes: All
Activation:

Next initiation of the recorder (RR).

If the drive has stored a previously recorded data vector, setting RL will invalidate

this data. Invalidated data cannot be retrieved.

See also:

RC

,

RG

,

RP[N]

,

RR

,

BH

Reference chapter in the

SimplIQ

Software Manual:

Chapter 7.4, ”The Recorder”

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-124