Lc - current limit flag, Simpliq – ElmoMC SimplIQ Command Reference User Manual
Page 95
LC - Current Limit Flag
Purpose:
Reports the status of the current limiting process. You may select two different current
limit specifications: The peak limit PL[1] specifies how much current can be applied to
the motor for short time periods (PL[2]) and the continuous limit CL[1] specifies how
much current can be applied to the motor continuously.
LC returns values according to the following table:
Value Description
0
The motor current is limited to the limit PL[1], or the motor is off.
1
The motor current is limited to the continuous limit CL[1].
Table 3-29: LC Return Values
Attributes: Type:
Status report, Integer
Scope:
Program, RS-232, CANopen
Restrictions: None
Unit modes: All
See also:
MC
,
PL[N]
,
CL[N]
Reference chapter in The
SimplIQ
Software Manual:
Chapter 10, ”The Current Controller”
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-82