An[n] - analog inputs array – ElmoMC SimplIQ Command Reference User Manual

Page 21

Advertising
background image

AN[N] - Analog Inputs Array

Purpose:
ƒ

AN[1] reports the analog input #1 value after offset correction (AS[1]), in volts.

ƒ

AN[2] reports the analog input #2 value after offset correction (AS[2]) in volts.

ƒ

AN[3] reports the measured current in the motor A phase, in amperes.

ƒ

AN[4] reports the measured current in the motor B phase, in amperes.

ƒ

AN[5] reports the measured current in the motor C phase, in amperes.

ƒ

AN[6] reports the line voltage value, in volts.

ƒ

AN[7] reports the duty cycle value of the PWM signal after offset correction in
fractional units

Attributes:

Type:

Status report, Real

Source:

Program, RS-232, CANopen

Restrictions: None
Unit modes: All

Typical applications:
1. Reading external sensors that provides +/- 10V
2. Reading analog or PWM references for either velocity or current
3. Reading phase currents and line voltage

Note:

ƒ

Analog input #1 serves as reference input for analog torque or analog

velocity command while in auxiliary reference mode (RM=1).

ƒ

AN[7] is available after the first MO=1.

ƒ

Each of Elmo’s

SimplIQ

drives support a different number of analog inputs.

For specific details consult the drive’s Installation Guide.

See also:

AG[N]

,

AS[N], PW[N]

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-8

Advertising