Notes:

ƒ

Changing YA[4] resets the position sensor thus resetting the homing position.

ƒ

Changing YA[5] does not change PY. It only defines in which direction future
encoder pulses will be counted.

ƒ

Changing the auxiliary sensor configuration while Output Compare is active may
cause unpredictable drive behavior. No warning or error is given.

ƒ

For some Output Compare signal sources, the auxiliary sensor must be configured
as output. Setting auxiliary sensor as input is illegal.

Attributes:

Type: Parameter,

Integer

Source:

Program, RS-232, CANopen

Restrictions: MO=0
Default values:

YA[1]…YA[3]=0 (RS), Non-volatile

YA[4]=2,

YA[5]=0

(RS), Non-volatile

Range:

As in previous table

Index range: [1…5]
Unit modes: All
Activation: Immediate

See also: OC