Attributes:
Type: Parameter,
Integer
Source:
Program, RS-232, CANopen
Restrictions: Advanced
model
only
Default values:
EM[1]=0, EM[2]=2, EM[3]=0, EM[4]=1000,
EM[5]=1, EM[6]=1, EM[7]=0, EM[8]=0
(RS),
Non-volatile
Range: EM[1]:
[0…2]
EM[2]:
[2…1024]
EM[3]:
Position counter range
EM[4]:
[1…32,000]
EM[5]:
[1…1023]
EM[6]:
[1…1024]
EM[7]:
1…32,000]
Index range: Write:
[1…7]
Read:
[1…8]
Unit modes:
UM=3, 4, 5
Activation:
See previous Notes
See also:
RM
,
FR[N]
Reference chapter in the SimplIQ Software Manual:
Chapter 12, ”The Position Reference Generator”
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-48