ST - Stop Motion

Purpose:
Stops the software motion. The software commands decelerate to a complete stop using
the SD deceleration. ST does not affect the external position reference and has no effect
for the following conditions: MO=0 and UM=1.

Attributes:

Type:

Command, No value

Source:

Program, RS-232, CANopen

Restrictions: None
Unit modes:

UM=2, 3, 4, 5

Activation: Immediate

See also:

BG

,

RM

Reference chapter in the

SimplIQ

Software Manual:

Chapter 12, ”The Position Reference Generator”

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)