Attributes:

Type: Parameter,

Integer

Source: RS-232,

CANopen

Restrictions: MO=0

for

PP[1]

Default values:

PP[1]=1, PP[2]=2, PP[13]=127, PP[14]=1,

PP[15]=128

All others default to zero (RS), Non-volatile

Range:

As shown in previous tables

Index range: [1…15]
Unit modes: All
Activation:

RS-232 parameters activated by setting PP[1].

CANopen parameters activated upon restarting

network through NMT service (refer to

Elmo CANopen Implementation Manual).

Notes:

ƒ

The number of R-232 stop bits is fixed to 1.

ƒ

The group ID number for CAN (PP[15]) defines the received message object ID.
The response is transmitted by each node with its own ID (PP[13]). Setting
PP[15]=128 allows the user to cancel the CAN group ID.

ƒ

Unused PP[N] parameters are reserved for compatibility with other Elmo drives.

Reference chapter in the

SimplIQ

Software Manual:

Chapter 3, ”Communication with the Host”

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-113