Wi[n] - miscellaneous reports, integer – ElmoMC SimplIQ Command Reference User Manual
Page 167
![background image](/manuals/558386/167/background.png)
WI[N] - Miscellaneous Reports, Integer
Purpose:
Reports integer constants and variables of the system usually used by the Composer
program rather than directly by the users.
Index Description
WI[1]
Minimum sampling time for torque control mode.
WI[2] Reserved.
WI[3] Reserved.
WI[4]
Maximum sampling time for torque control mode.
WI[5] Reserved.
WI[6] Reserved.
WI[7]
Available CPU time for background tasks, remaining after real-time
control algorithm performance.
WI[8]
First amplitude for the auto-phasing process.
WI[9]
Second amplitude for the auto-phasing process.
WI[10]
First oscillation phase for the auto-phasing process.
WI[11]
Second oscillation phase for the auto-phasing process.
WI[12]
Oscillation phase average for the auto-phasing process.
WI[13]
Integer that shows entire estimated sampling time, in microseconds.
WI[14]
Integer (unsigned short) that shows a fraction of estimated sampling
time, in microseconds. The value of the estimated sampling time is
calculated according to the following formula: WI[13] + WI[14]/2^16.
WI[21] Actual
length
of
each recorded vector.
WI[22]
Maximum valid value of SF for current TS value.
WI[23]
Returns 1 if the Harmonica is running from the RAM and 0 if it is
running from the flash.
Table 3-48: WI[N] Report Details
Attributes:
Type:
Command/Status report, Integer
Source:
Program, RS-232, CANopen
Restrictions: None
Unit modes: All
See also:
WS[N]
Reference chapters in the
SimplIQ
Software Manual:
Chapter 8, “The Recorder;” Chapter 9, “Commutation”
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-154