BT - Begin Motion at Defined Time

Purpose:
Starts motion at the defined time. This command is designed to start the simultaneous
motion of several axes. It is similar to the BG command with the following difference: BG
starts motion immediately whereas BT begins at the defined time.

Syntax:
BT=N
where N is the absolute time in microseconds

Attributes:

Type: Command,

Integer

Source:

Program, RS-232, CANopen

Restrictions: MO=1
Unit modes:

UM=2, 3, 4, 5