BT - Begin Motion at Defined Time
Purpose:
Starts motion at the defined time. This command is designed to start the simultaneous
motion of several axes. It is similar to the BG command with the following difference: BG
starts motion immediately whereas BT begins at the defined time.
Syntax:
BT=N
where N is the absolute time in microseconds
Attributes:
Type: Command,
Integer
Source:
Program, RS-232, CANopen
Restrictions: MO=1
Unit modes:
UM=2, 3, 4, 5
See also:
BG
,