Lp[n] - list properties, Simpliq – ElmoMC SimplIQ Command Reference User Manual
Page 98
![background image](/manuals/558386/98/background.png)
LP[N] - List Properties
Purpose:
Sets the properties of the serial flash data upload and download by the next LS and DL
commands.
LP[1] sets the start byte address of the next LS transmission, or the byte address for
starting the storage of the next DL transmission.
LP[2] sets the size — in bytes — to be transmitted at the next LS.
LP[3] returns the start byte address of the user program (read only).
LP[4] returns the size of the user program storage (read only).
Attributes:
Type: Parameter,
Integer
Scope: RS-232,
CANopen
Restrictions: None
Default values:
LP[1] and LP[2] set to 0 on power on
Range: LP[1]:
[0…262,144]
LP[2]:
[0…247]
Index range: [1…4]
Unit modes: All
Activation: Immediate
See also:
CC
,
DL
,
LS
Reference chapter in the
SimplIQ
Software Manual:
Chapter 6, ”Program Development and Execution”
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-85