LP[N] - List Properties

Purpose:
Sets the properties of the serial flash data upload and download by the next LS and DL
commands.
ƒ

LP[1] sets the start byte address of the next LS transmission, or the byte address for
starting the storage of the next DL transmission.

ƒ

LP[2] sets the size — in bytes — to be transmitted at the next LS.

ƒ

LP[3] returns the start byte address of the user program (read only).

ƒ

LP[4] returns the size of the user program storage (read only).

Attributes:

Type: Parameter,

Integer

Scope: RS-232,

CANopen

Restrictions: None
Default values:

LP[1] and LP[2] set to 0 on power on

Range: LP[1]:

[0…262,144]

LP[2]:

[0…247]

Index range: [1…4]
Unit modes: All
Activation: Immediate

See also:

CC

,

DL

,

LS

Reference chapter in the

SimplIQ

Software Manual:

Chapter 6, ”Program Development and Execution”

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)