ElmoMC SimplIQ Command Reference User Manual
Page 149
Advertising
![background image](/manuals/558386/149/background.png)
0x8 0x4 0x2 Meaning
0 0 0 OK.
0
0
1
Under voltage: The power supply is shut off or it has too high an
impedance.
0
1
0
Over voltage: The power supply voltage is too large, or the servo
drive did not succeed in absorbing the kinetic energy while
braking a load. A shunt resistor may be needed.
1
0
1
Short circuit: The motor or its wiring may be defective.
1
1
0
Temperature: The drive is overheating.
Table 3-46: Servo Drive Status Indications
Attributes:
Type:
Status report, Integer, Bit-field
Source:
Program, RS-232, CANopen
Restrictions: None
Unit modes: All
See also:
MF
,
RR
,
PM
,
UM
,
RM
,
IP
,
MS
,
MO
,
LC, HM, HY
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-136
Advertising