background image

Error
Code


Error String / Description


Example / Remedy

45

Returned error from subroutine.
Occurs when a return op-code has no valid
address to return to.

46

May not use multi-capture homing mode
with stop event.
Occurs when trying to set multiple capture
events with a STOP between events.

The following cannot be set:
HM[4]=0; HM[1]=3.

47

User program does not exist. XQ or XC
returns this error if a program has not been
loaded to and successfully verified by the
drive.

50 Stack

overflow.

A CPU exception was detected.
This error reflects either a hardware
problem or a faulty power supply.

Use the CD command to
determine the details of what has
occurred. If “Called handler” is
“none” and “Failure address” is
non-zero, then TS is too short
and there was a real-time
overflow. Record the entire
string of the CD command and
call your service center for
technical support.

53 Only

for

current.

Command is applicable only in torque
control modes UM=1 or 3.

TC=2 (Set torque to 2A) is an
error in UM=2, because in this
mode, the torque command is set
automatically by the controller so
as to achieve the desired speed.

54 Bad

database.

Cannot start the motor, because the setup
data is not consistent.

If CA[4]==CA[5], two physical
Hall sensors are defined as the
same logical sensor, thereby
preventing powering the motor.

55 Bad

context.

A command that is not applicable in the
present context has been attempted.

This error is caused by privileged
commands used in auto-setup
sessions.

56

The product grade does not support this
command.

User may have attempted to set
or activate features that are
available only for the Advanced
SimplIQ models.

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-35

Advertising