KI[N], KP[N] - PI Parameters

Purpose:
ƒ

KI[1], KP[1] defines the PI current control filter.

ƒ

KI[2], KP[2] defines the PI velocity control filter.

ƒ

KP[3] defines the gain of the position controller.

The parameters KP[2], KI[2] and KP[3] apply only if the controller gains are fixed (gain
scheduling is not used: GS[2]=0).

Attributes:

Type: Parameter,

Real

Source:

Program, RS-232, CANopen

Restrictions: None
Default values: RS=0
Range: KI[N]>0
KP[N]>0
Index range: [1…3]

See also:

KV[N]

,

GS[N]

Reference chapters in The

SimplIQ

Software Manual:

Chapter 10, ”The Current Controller;” Chapter 15, “The Controller”

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-79